Buy now 11 000 €
ref : 13561
Year of mfg. : 2015
Available on 2026-12-01
Latest check up : 2026
Possible installation on quotation
Used equipment inspected by our experts
Functional condition: very good
Cosmetic condition: very good
Zeiss reliability and precision
Express shipping available upon request
The ZEISS HFA III 850 is a high-end automated perimetry system designed for visual field testing, glaucoma diagnosis, and monitoring of disease progression.
It is part of the Humphrey Field Analyzer 3 series from Carl Zeiss Meditec.
Compared to the HFA III 840, it notably features blue-yellow perimetry (SWAP) and additional examination control functions.
Technical Specifications
HFA III 850 Specifications
Manufacturer: Carl Zeiss Meditec
Technology: Automated static and kinetic perimetry
Maximum temporal field: 90°
Examination distance: 30 cm
Stimulus duration: 200 ms
Background illumination: 31.5 apostilbs
Goldmann I–V stimulus sizes
Touchscreen LCD
Gaze tracking
Head tracking
Vertex monitoring
SWAP blue-yellow perimetry
GPA and VFI progression analysis
Automatic optical correction: No
Programs and features
- 24-2 / 24-2C: central visual field testing for glaucoma.
- 30-2: neurological and glaucoma screening.
- 10-2: detailed analysis of the central visual field.
- 60-4: Peripheral examination.
- SITA Standard, Fast, and Faster: Examination strategies.
- SITA-SWAP: Blue-yellow perimetry.
- Esterman: Functional assessment of the visual field.
- RelEYE: retrospective visualization of the eye during the examination.
- GPA: analysis of glaucoma progression.
Comparison of ZEISS HFA III Models
Function 830 / 840 / 850 / 860
SITA Faster Yes / Yes / Yes / Yes
Gaze Tracking No / Yes / Yes / Yes
Head Tracking No / Yes / Yes / Yes
Vertex Monitoring No / No / Yes / Yes
Blue-Yellow SWAP No / No / Yes / Yes
RelEYE No / No / Yes / Yes
Liquid Trial Lens No / No / No / Yes
Dimensions and Weight
Width: 51 cm
Depth: 46 cm
Height: 58 cm
Weight: approximately 28.7 kg, excluding the table.
There was an error when considering the interest of the product. Please try or contact the support.
Your partnership request has been sent by email to the OPHTAZON team.
Your partnership request has been sent by email to the OPHTAZON team.
Your application for a partnership was not successful. Please try again or contact the support.
HOME
sales@ophtazon.com / +33 141 515 490
INTERNATIONAL SALES MANAGER
M. Sadreddine MEHRI
sadreddine.mehri@ophtazon.com / +33 6 08 84 07 42
TECHNICAL & SALES MANAGER IVORY COAST
M. Khaled SELLAMI
khaled.sellami@ophtazon.com / +225 07 68 46 36 14
Nous utilisons différentes technologies pour optimiser votre expérience utilisateur.
Merci de cliquer sur le bouton pour donner votre accord.
Vous souhaitez en savoir plus ? Cliquez ici